PVC 3 & 4 Core Round Submersible Pump Cable |
|
| Construction |
- Conductor
High purity electrolytic grade bright annealed flexible bunched bare,
copper conductor according to international standards like IS 8130,
BS 6360, IEC 228 & VDE 0295.
- Insulation
Specially developed dielectric grade PVC Compound impervious to
water, oils, grease etc.
- Sheath
Sheathing by High abrasion resistant tough & flexible PVC Compound
|
| Standards |
- IS 694, BS 6500, IEC 60227, CEI 20-20, VDE 0281, SABS 1574,
AS 3191, AS/NZS 5000.1, HD 21.1, NF C 32-201, French Standard 32-102-16
|
| Working Voltage Uo/U |
- 450/ 750 V, 600/ 1000 V, 650/1100 V
|
| Test Voltage |
|
|
| Temperature range |
|
|
|
| Core colors |
(For Asian, African Markets) |
(For European Markets) |
| 3 core |
Red ,Yellow, Blue |
Black, Blue, Brown |
| 4 core |
Red ,Yellow, Blue, Green |
Black, Blue, Brown, Green |
| Sheath color: |
Choice of Black or Blue |
Choice of Black or Blue |
| |
 |
 |
| |
 |
 |
|
PVC 3 core Round Submerisble Cable
|
Nos. of Cores
X Size
sq.mm
|
No./
size of
wire
no./mm
|
Insulation
thickness
(nom.)
mm
|
Sheath
thickness (nom.)
mm
|
Overall
dimensio
ns
(approx.)
mm |
Conductor
resistance
at 20° C
(max.)
ohm/km |
Current
carrying
capacity at
40° C
amps. |
| 3 x 1.5 |
22/.3 |
0.6 |
0.9 |
8.6 |
12.1 |
14 |
| 3 x 2.5 |
36/.3 |
0.7 |
1.0 |
9.8 |
7.41 |
18 |
| 3 x 4 |
56/.3 |
0.8 |
1.0 |
11.5 |
4.95 |
26 |
| 3 x 6 |
84/.3 |
0.8 |
1.1 |
13.3 |
3.3 |
31 |
| 3 x 10 |
140/.3 |
1 |
1.2 |
16.5 |
1.91 |
42 |
| 3 x 16 |
226/.3 |
1 |
1.3 |
19.7 |
1.21 |
57 |
| 3 x 25 |
354/.3 |
1.2 |
1.5 |
24.0 |
0.78 |
72 |
| 3 x 35 |
495/.3 |
1.2 |
1.6 |
27.0 |
0.554 |
90 |
| 3 x 50 |
703/.3 |
1.4 |
1.7 |
31.3 |
0.386 |
115 |
| 3 x 70 |
360/.5 |
1.4 |
2.0 |
37.3 |
0.272 |
143 |
| 3 x 95 |
475/.5 |
1.6 |
2.0 |
43.3 |
0.206 |
165 |
|
PVC 4 core Round Submerisble Cable
|
Area (nom)
sq.mm
|
Nos./
size of
wire
no./mm
|
Insulation
thickness
(nom.)
mm
|
Sheath
thickness
(nom.)
mm
|
Overall
dimensions
(approx.)
mm
|
Conductor
resistance
at 20° C
(max.)
ohm/km |
Current
carrying
capacity at
40° C
amps. |
| 4 x 1.5 |
22/.3 |
0.6 |
0.9 |
9.4 |
12.1 |
14 |
| 4 x 2.5 |
36/.3 |
0.7 |
1.0 |
10.8 |
7.41 |
18 |
| 4 x 4 |
56/.3 |
0.8 |
1.0 |
12.7 |
4.95 |
26 |
| 4 x 6 |
84/.3 |
0.8 |
1.2 |
14.8 |
3.3 |
31 |
| 4 x 10 |
140/.3 |
1 |
1.3 |
18.4 |
1.91 |
42 |
| 4 x 16 |
226/.3 |
1 |
1.4 |
21.8 |
1.21 |
57 |
| 4 x 25 |
354/.3 |
1.2 |
1.6 |
26.8 |
0.78 |
72 |
| 4 x 35 |
495/.3 |
1.2 |
1.7 |
30.2 |
0.554 |
90 |
| 4 x 50 |
703/.3 |
1.4 |
1.8 |
34.9 |
0.386 |
115 |
| 4 x 70 |
360/.5 |
1.4 |
2.0 |
41.4 |
0.272 |
143 |
| 4 x 95 |
475/.5 |
1.6 |
2.2 |
48.1 |
0.206 |
165 |
|
| |
| Note: |
| Insulation thickness, Sheath thickness and overall dimensions are nominal values. The number of wires is approximate and strand diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance as per IS 8130/1984, BS-6360, IEC-60228 & VDE-0295. |
| |
|
|